SG Security Communications MLR2-E Instrukcja Użytkownika Strona 27

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 59
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 26
Form Number.: 7-3005 File Name: SG Automation Output Revision/Date: 01/May 3, 2005
Department: Engineering
Division: Embedded Software Form Template Owner: Jeff Cougler
27
Panel sends:
1234555515556
Description: System Message
Panel sends:
1234355555556
Description: AC Restoral
Auxiliary Code 7 Example
Zone alarm status report, alarms are reported in previous 8 channels.
Panel sends:
1234155555557
Description: alarm zone 1
Panel sends:
1234555555517
Description: alarm zone 8
Panel sends:
1234155555537
Description: alarm zone 1, restoral zone 8
Auxiliary Code 8 Example
New low battery (will not send restore)
Panel sends:
1234155555558
Description: Alarm zone 1 and Low Battery
Auxiliary Code 9 Example
Test report, alarm status is reported in previous 8 channels.
Panel sends:
1234155555559
Description: Alarm zone 1 and Test Report
Auxiliary Code 0 Example
Radio diagnostics, radio testing inf. reported in previous 8 channels.
Panel sends:
1234555155550
Description: Radio Diagnostic Zone 4
Przeglądanie stron 26